*****USE UH15B120FE-A********** *******************************

UH15B120FE MFG #: 15B412003110209
  • AFUE Rating: 82 Percent, 82%
  • AGA Input Rating: 120 MBH
  • Gas Type: Natural, Natural Gas
  • Net IBR Rating: 85 MBH
Gas Fired Boiler; Type Hot Water; Supply Connection 1-1/4 Inch; Return Connection 1-1/4 Inch; Gas Type Natural; Gas Connection 1/2 Inch; AGA Input Rating 120 MBH; DOE Heating Capacity 98 MBH; Net IBR Rating 85 MBH; AFUE Rating 82 Percent; Boiler Dimensions 19 Inch Length x 29-1/8 Inch Width x 30-3/4 Inch Height; Boiler Height Including Draft Hood 36-5/16 Inch; Boiler Material Cast Iron; Water Content 5.6 Gallon; Ignition Type Intermittent Electric Pilot; Venting Type Automatic, Horizontal; Vent Size 6 Inch; Relief Valve Details ASME Relief Valve Supplied; ASME Code Yes; Pressure Rating 100 PSI; Mounting Type Floor Mount; Warranty 20 Year Limited; Options Hydro Level Control, Low Water Cut-Off, Central Heating Pump; Inclusions/Features Boiler Jacket, Cast-Iron Boiler Battery, Vent Damper Relay, Circulator, Main Gas Burner, High Limit Control, Automatic Gas Valve, Gas Pressure Regulator, Safety Shut-Off, Pilot Flow Adjustment, Pilot Filter, Drain Valve, Spill Switch, Rollout Switch, Automatic Vent Damper, Wiring Harness, Non-Linting Safety Pilot; Applicable Standard ASME H, AHRI, ANSI Z223.1/NFPA 54, ANSI/ASME CSD-1, CSA (US), CAN/CSA B149.1; Input Supply Rating 120 Volt AC at 60 Hertz 15 Amp; Number of Burner 3; Application Commercial and Residential
  • Ignition Type
  • Gas Type
  • Gas Connection
  • Water Content
  • Options
  • Inclusions/Features
  • Supply Connection
  • ASME Code
  • Warranty
  • Net IBR Rating
  • AGA Input Rating
  • Venting Type
  • Relief Valve Details
  • Type
  • AFUE Rating
  • Vent Size
  • Applicable Standard
  • Mounting Type
  • DOE Heating Capacity
  • Boiler Dimensions
  • Boiler Height Including Draft Hood
  • Pressure Rating
  • Return Connection
  • Boiler Material
  • IsInactive
Intermittent Electric Pilot
Natural Gas
1/2 Inch
5.6 Gallon
Hydro Level Control, Low Water Cut-Off, Central Heating Pump
Boiler Jacket, Cast-Iron Boiler Battery, Vent Damper Relay, Circulator, Main Gas Burner, High Limit Control, Automatic Gas Valve, Gas Pressure Regulator, Safety Shut-Off, Pilot Flow Adjustment, Pilot Filter, Drain Valve, Spill Switch, Rollout Switch, Auto
1-1/4 Inch
Yes
20 Year Limited
85 MBH
120 MBH
Automatic, Horizontal
ASME Relief Valve Supplied
Hot Water
82%
6 Inch
ASME H, AHRI, ANSI Z223.1/NFPA 54, ANSI/ASME CSD-1, CSA (US), CAN/CSA B149.1
Floor Mount
98 MBH
19 Inch Length x 29-1/8 Inch Width x 30-3/4 Inch Height
36-5/16 Inch
100 PSI
1-1/4 Inch
Cast Iron
true