! BOILER NAT GAS 175 mbh UTICA ******CLOSEOUT*****************

MGB175HID MFG #: MGB170J
  • AFUE Rating: 82%
  • AGA Input Rating: 170 MBH
  • Gas Type: Natural/Propane
  • Input Capacity: 175 mbh
  • Net IBR Rating: 121 MBH
Gas Fired Boiler; Type Hot Water; Supply Connection 1-1/4 Inch Threaded; Return Connection 1-1/4 Inch Threaded; Gas Type Natural/Propane; Gas Connection 1/2 Inch Threaded; AGA Input Rating 170 MBH; DOE Heating Capacity 139 MBH; Net IBR Rating 121 MBH; AFUE Rating 82 Percent; Boiler Dimensions 22-3/4 Inch Length x 27 Inch Width x 30-3/4 Inch Height; Boiler Height Including Draft Hood 38-3/4 Inch; Boiler Material Cast Iron; Water Content 7.2 Gallon; Ignition Type High Limit/Electronic, Intermittent Pilot; Burner Type Stainless Steel; Venting Type Atmospheric, Automatic; Vent Size 7 Inch; Relief Valve Details ASME Relief Valve Supplied; Pressure Rating 100 PSI; Mounting Type Floor Mount; Warranty Lifetime Limited; Options Central Heating Pump (Taco, Grundfos, B and G or Less Pump), LP Conversion Kit, Combustible Floor Plate, Fill-Trol; Inclusions/Features Cast Iron Push Nipple, Automatic Gas Valve, Gas Pressure Regulator, Automatic Pilot, Safety Shut-Off, Pilot Flow Adjustment, Pilot Filter; Applicable Standard ASME H, AHRI, ANSI Z223.13, ANSI Z223.1/NFPA 54, CSA (US), CAN/CSA B149.1; Input Supply Rating 120 Volt AC at 60 Hertz 1-Phase 12 Amp; Number of Burner 4; Application Residential
  • Gas Connection
  • Water Content
  • Options
  • Inclusions/Features
  • Type
  • AFUE Rating
  • Vent Size
  • Applicable Standard
  • Supply Connection
  • Warranty
  • Gas Type
  • Ignition Type
  • Mounting Type
  • AGA Input Rating
  • Venting Type
  • Relief Valve Details
  • DOE Heating Capacity
  • Boiler Dimensions
  • Boiler Height Including Draft Hood
  • Burner Type
  • Pressure Rating
  • Net IBR Rating
  • Input Capacity
  • Return Connection
  • Boiler Material
  • IsInactive
1/2 Inch Threaded
7.2 Gallon
Central Heating Pump (Taco, Grundfos, B and G or Less Pump), LP Conversion Kit, Combustible Floor Plate, Fill-Trol
Cast Iron Push Nipple, Automatic Gas Valve, Gas Pressure Regulator, Automatic Pilot, Safety Shut-Off, Pilot Flow Adjustment, Pilot Filter
Hot Water
82%
7 Inch
ASME H, AHRI, ANSI Z223.13, ANSI Z223.1/NFPA 54, CSA (US), CAN/CSA B149.1
1-1/4 Inch Threaded
Lifetime Limited
Natural/Propane
High Limit/Electronic, Intermittent Pilot
Floor Mount
170 mbh
Atmospheric, Automatic
ASME Relief Valve Supplied
139 MBH
22-3/4 Inch Length x 27 Inch Width x 30-3/4 Inch Height
38-3/4 Inch
Stainless Steel
100 PSI
121 mbh
175 mbh
1-1/4 Inch Threaded
Cast Iron
true